VEGA

Point level measurement with vibrating level switches 

In point level measurement with vibrating level switches, a rod or a fork is set vibrating. When the vibrating probe comes into contact with the medium, the vibration changes and the device outputs a switching command. Vibrating level switches are used in liquids as well as in granular and powdery bulk solids.

The advantages

Vibration rods are easy to clean and measure reliably regardless of grain size and position.
The switching accuracy of vibrating level switches with tuning fork are not influenced by material deposits or buildup.

Select a suitable level switch using the technical data.

VEGASWING 51

VEGASWING 51
Material
316L
Process fitting
thread from G, NPT
hygienic fittings
Process temperature
-40 +150 C 
Process pressure
-1 +64 bar
(-100 +6400 kPa) 

VEGASWING 61

VEGASWING 61
Materials
316L, Hastelloy, ECTFE,
PFA, enamel
Process fitting
thread from G, NPT
flanges from DN 25, 1"
hygienic fittings
Process temperature
-50 +250 C 
Process pressure
-1 +64 bar (-100 +6400 kPa) 
SIL qualification
optionally up to SIL2

VEGASWING 63

VEGASWING 63
Version
tube extension up to 6 m
Materials
316L, ECTFE, PFA
Hastelloy, enamel
Process fitting
thread from G, NPT
flanges from DN 25, 1"
hygienic fittings
Process temperature
-50 +250 C 
Process pressure
-1 +64 bar
(-100 +6400 kPa) 
SIL qualification
optionally up to SIL2

VEGASWING 66

VEGASWING 66
Material
316L, Inconel 718, Hastelloy
Process fitting
thread from G1, 1 NPT
flanges from DN 40, 2"
Process temperature
-196 +450 C
Process pressure
-1  +160 bar
(-100 +16.000 kPa)
SIL qualification
up to SIL2
(homogeneous redundancy up to SIL3)

VEGAVIB 61

VEGAVIB 61
Measuring range
bulk solids from 20 g/l
Process fitting
thread from G1, 1 NPT
flanges from DN 50, 2"
hygienic fittings
Process temperature
-50 +250 C 
Process pressure
-1 +16 bar
(-100 +1600 kPa)
SIL qualification
optionally up to SIL2

VEGAVIB 62

VEGAVIB 62
Version
suspension cable up to 80 m
Measuring range
bulk solids from 20 g/l
Process fitting
thread from G1, 1 NPT
flanges from DN 50, 2"
hygienic fittings
Process temperature
-50 +150 C
Process pressure
-1 +6 bar
(-100 +600 kPa)
SIL qualification
optionally up to SIL2

VEGAVIB 63

VEGAVIB 63
Version
tube extension up to 6 m
Measuring range
bulk solids from 20 g/l
Process fitting
thread from G1, 1 NPT
flanges from DN 50, 2"
hygienic fittings
Process temperature
-50 +250 C 
Process pressure
-1 +16 bar
(-100 +1600 kPa) 
SIL qualification
optionally up to SIL2

VEGAWAVE 61

VEGAWAVE 61
Measuring range
bulk solids from 8 g/l
Process fitting
thread G1, 1 NPT
flanges from DN 50, 2"
Process temperature
-50 +250 C 
Process pressure
-1 +25 bar
(-100 +2500 kPa)
SIL qualification
optionally up to SIL2

VEGAWAVE 62

VEGAWAVE 62
Version
suspension cable up to 80 m
Measuring range
bulk solids from 8 g/l
Process fitting
thread G1, 1 NPT
flanges from DN 50, 2"
Process temperature
-50 +150 C
Process pressure
-1 +6 bar
(-100 +600 kPa)
SIL qualification
optionally up to SIL2

VEGAWAVE 63

VEGAWAVE 63
Version
tube extension up to 6 m
Measuring range
bulk solids from 8 g/l
Process fitting
thread G1, 1 NPT
flanges from DN 50, 2"
Process temperature
-50 +250 C
Process pressure
-1 +25 bar
(-100 +2500 kPa)