VEGA

Process pressure measurement  

Pressure sensors detect the pressure in pipes or closed vessels. Inside the sensor, the deflection of a membrane is converted into a measuring signal. Different measuring cells are used for pressure detection.

The advantages

Ceramic measuring cells offer the advantage of excellent long-term stability and high overload resistance. Metallic measuring cells also cover higher measuring ranges.

Select a suitable sensor using the technical data.

» VEGABAR 14

VEGABAR 14
Measuring cell
CERTEC®
Measuring range
-1 … +60 bar (-100 … +6000 kPa)
Process fitting
thread from G˝, ˝ NPT
Process temperature
-40 … +100 °C
Deviation in characteristics
0.3 %

» VEGABAR 17

VEGABAR 17
Measuring cell
piezoresistive/thin film strain gauge
Measuring range
-1 … +1000 bar (-100 … +100000 kPa)
Process fitting
thread from G˝, ˝ NPT
Process temperature
-40 … +150 °C
Deviation in characteristics
0.5 %

» VEGABAR 81

VEGABAR 81
Measuring cell
chemical seal system
Measuring range
-1 … +1000 bar
(-100 ... +100000 kPa)
Process fitting
thread from G˝, ˝ NPT
flanges from DN 25, 1"
hygienic fittings
Process temperature
-90 ... +400 °C
Accuracy class
0,2 %

» VEGABAR 82

VEGABAR 82
Measuring cell
CERTEC®, MINI-CERTEC®
Measuring range
-1 … +100 bar
(-100 ... +10000 kPa)
Process fitting
thread from G˝, ˝ NPT
flanges from DN 15, 1˝"
hygienic fittings
Process temperature
-40 … +150 °C
Accuracy class
0,2 %; 0,1 %; 0,05 %

» VEGABAR 83

VEGABAR 83
Measuring cell
piezoresisitive/thin film strain gauge/METEC®
Measuring range
-1 … +1000 bar
(-100 ... +100000 kPa)
Process fitting
thread from G˝, ˝ NPT
flanges from DN 25
hygienic fittings
Process temperature
-40 ... +200 °C
Accuracy class
0,2 %; 0,1 %; 0,075 %

» VEGABAR 51

VEGABAR 51
Measuring cell
chemical seal system
Measuring range
-1 … +400 bar (-100 … +40000 kPa)
Process fitting
flanges from DN 25, 1"
Process temperature
-40 … +400 °C
Deviation in characteritics
0.2 %
SIL qualification
optionally up to SIL2

» VEGABAR 52

VEGABAR 52
Measuring cell
CERTEC
Measuring range
-1 … +60 bar (-100 … +6000 kPa)
Process fitting
thread from G˝, ˝ NPT
flanges from DN 25, 1˝"
hygienic fittings
Process temperature
-40 … +150 °C
Deviation in characteristics
0.2 %; 0.1 %; 0.075 %
SIL qualification
optionally up to SIL2

» VEGABAR 53

VEGABAR 53
Measuring cell
piezoresisitive/thin film strain gauge
Measuring range
-1 … +1000 bar (-100 … +100000 kPa)
Process fitting
thread from G˝, ˝ NPT
flanges from DN 40
hygienic fittings
Process temperature
-40 … +150 °C
Deviation in characteristics
0.2 %; 0.1 %; 0.075 %
SIL qualification
optionally up to SIL2

» VEGABAR 54

VEGABAR 54
Measuring cell
MINI-CERTEC®
Measuring range
-1 … +60 bar (-100 … +6000 kPa)
Process fitting
thread from G˝
flanges from DN 25, 1"
hygienic fittings
Process temperature
-40 … +120 °C
Deviation in characteristics
0,2 %, 0,1 %
SIL qualification
optionally up to SIL2

» VEGABAR 55

VEGABAR 55
Measuring cell
METEC®
Measuring range
-1 … +25 bar (-100 … +2500 kPa)
Process fitting
thread from G˝, ˝ NPT
flanges from DN 25
Process temperature
-12 … +200 °C
Deviation in characteristics
0.2 %; 0.1 %; 0.075 %
SIL qualification